DP-360 DOCSIS Protocol Analyzer

Technical Specifications

DP-360 hardware overview

Chassis - 19” rackmount chassis, 4U

  • 19”Wx7”Hx12.5”D (48cm x 18cm x 29cm)
  • Weight - 28 lbs
  • Power Supply (90-250VAC, 50-60Hz, Autosensing, Fused)
  • Integrated Cooling: Left to Right, Front to Rear
DOCSIS Protocol Analyzer
DP-360 - DOCSIS Protocol Analyzer - Technical Specifications

General specifications

Protocol compliance:

Data capture:
Operating system:
Remote host requirements:

Ethernet interfaces:
RF input connectors:
Powering:
Operating temperature:
Chassis type:
DOCSIS / Euro-DOCSIS J.83 1.0, 1.1, 2.0, 3.0
RAM 2 GB
Windows XP Pro
PC/Laptop with Windows XP/Vista
10/100/1000 MB
75 ohm, F (one D/S and one U/S)
100-240 VAC, 50/60 Hz, 300W
15-35 Celsius
4RU Compact PCI

Downstream specifications

RF frequency range:
Input level:
Modulation levels:
Filters:
Bandwidth:
111-1000 MHz
-10 to +10 dBmV
64-QAM and 256-QAM
D/S message Types, MAC address, configurable on a per channel basis
6MHz and 8MHz

Upstream specifications

RF frequency range:
Input level:
Modulation levels:

Filters:
Bandwidth:
5-85 MHz
-10 to +10 dBmV
QPSK, 8-QAM, 16-QAM, 32-QAM, 64-QAM in TDMA, A-TDMA and S-CDMA. 128-QAM supported in S-CDMA TCM mode
U/S message types, MAC address, configurable on a per channel basis
200KHz, 400KHz, 800KHz, 1.6MHz, 3.2MHz and 6.4MHz

Software Specifications

DP-360 Master Control Software

  • Main application that configures and controls the DP-360 hardware
  • Automatically started on boot-up
  • Loads firmware, performs diagnostics, remote login, etc.
  • Communicates with DP-360 GUI and APIs

DP-360 GUI

  • User GUI used to operate and control the DP-360 hardware.
  • Double-click to start
  • Can be run locally or over a TCP/IP connection

DP-360 DAS

  • DOCSIS Analysis Software
  • Format, view and analyze captured DOCSIS data

Automation Software

  • Control API – Web Service
  • Analysis API – TCL and C callable .dll files